—— Chemical DPC Injection for Rising Damp

Premium Silane/Siloxane DPC Injection Material

A high-fluidity liquid injection material designed to form a chemical damp-proof barrier against capillary rising moisture in masonry walls.

Single-component, solvent-free system for professional rising damp treatment in brick, stone and other porous masonry.

≥85%

Active Ingredient Content

≥97%

Water Absorption Reduction

1K

Single-component System

Solvent-Free

Professional DPC Injection

Product Overview

What Is Silane/Siloxane DPC Injection Material?

Silane/Siloxane DPC Injection Material is a liquid chemical damp-proof course used to control rising damp caused by capillary moisture in masonry walls. After injection into drilled holes near the base of the wall, the material penetrates the porous masonry and forms a water-repellent chemical barrier that reduces further upward moisture movement.

YURU Premium Silane/Siloxane DPC Injection Material is a single-component system based on reactive polydimethylsiloxanes in emulsion. Its high fluidity and wettability help the material distribute through porous masonry while maintaining the original breathability and appearance of the treated wall.

Important Application Note

This product is specifically designed for capillary rising damp. Moisture caused by plumbing leaks, condensation, rain penetration or lateral groundwater pressure should be diagnosed separately before selecting a DPC injection treatment.

Technical Snapshot

Product at a Glance

SystemSingle-component
Base ChemistryReactive polydimethylsiloxanes in emulsion
Main FunctionChemical barrier against capillary rising damp
Active Ingredient Content≥85%
Water Absorption Reduction≥97%
Catalysis TimeApprox. 8–10 days

Need complete technical parameters and application data?

Rising Damp Problem

Designed to Control Capillary Rising Damp

A chemical DPC injection system targets moisture that rises through porous masonry by capillary action, helping interrupt the upward movement of water within the wall.

01

Rising Damp

Moisture rises from the ground through the capillary pores of brick, stone and other porous masonry where an effective damp-proof course is missing or no longer performing as intended.

02

Salt Efflorescence

Rising moisture can transport soluble salts through masonry, leading to visible salt deposits on wall surfaces and contributing to ongoing deterioration.

03

Flaking or Damaged Plaster

Persistent dampness and salt movement can contribute to peeling, powdering or flaking plaster in the lower part of affected walls.

04

Persistent Damp Walls

After the chemical barrier is established, further capillary moisture rise is reduced and the wall can begin to dry naturally over time.

Typical signs do not always mean rising damp

Damp staining, peeling finishes or salt deposits can have different causes. The moisture source should be identified before selecting a chemical DPC injection material.

Material Selection

When Is Chemical DPC Injection Suitable?

Chemical DPC injection is intended for masonry affected by capillary rising damp. Suitability depends on the moisture source, wall construction, masonry type and the ability of the injection material to distribute through the wall section.

Wall / Moisture ConditionSuitabilitySelection Consideration
Capillary rising damp from ground level Recommended Application Designed specifically to form a chemical barrier against upward capillary moisture movement.
Missing or ineffective damp-proof course Suitable for Evaluation Chemical injection can create a horizontal moisture-control zone within the masonry.
Red brick masonry Suitable Red brick is included among the treatable masonry materials in the product instructions.
Solid / hollow concrete blocks Suitable Suitable where the wall construction allows effective injection and material distribution.
Stone or rubble masonry Suitable Designed for porous mineral masonry including stone-based wall materials.
Condensation Not Primary Solution Condensation is not caused by capillary rising moisture and requires separate moisture diagnosis.
Plumbing leakage Not Primary Solution The water source should first be repaired or isolated.
Rain penetration Separate Diagnosis External water entry should be diagnosed and addressed independently from rising damp.
Lateral groundwater pressure Different Waterproofing Strategy Lateral water pressure is different from capillary rising damp and may require another waterproofing system.

Use DPC Injection When

  • Moisture is rising from the lower wall zone.
  • The wall is constructed from porous masonry.
  • A horizontal chemical moisture barrier is required.
  • The wall can be safely drilled and injected.
  • The moisture source has been identified as rising damp.

Do Not Select DPC Injection Based Only On

  • A damp-looking wall.
  • Surface mold or discoloration.
  • Paint blistering alone.
  • Salt deposits without moisture diagnosis.
  • Below-grade water pressure or uncontrolled leakage.

Before Selecting DPC Injection, Check:

Not Sure Whether DPC Injection Fits Your Wall?

Send us the wall material, wall thickness, moisture condition and available project photos for preliminary material evaluation.

Working Principle

How Does the Chemical DPC Work?

The liquid injection material penetrates porous masonry and develops a water-repellent chemical barrier that helps interrupt further capillary moisture rise.

01

Injected into the Lower Wall Zone

The liquid material is introduced into drilled holes near the base of the affected wall using pressure injection or gravity feed, depending on the wall condition and application method.

02

High-Fluidity Penetration

Its high fluidity and wettability help the material spread through porous masonry and reach the wall section surrounding the injection zone.

03

Hydrophobic Chemical Barrier

The reactive siloxane system develops a water-repellent chemical zone within the masonry, helping reduce the upward movement of moisture caused by capillary action.

04

Natural Wall Drying

Once the chemical barrier is established, further rising moisture is reduced and the existing damp wall can begin to dry naturally. Drying time varies according to wall thickness, masonry type and existing moisture conditions.

Catalysis Time: Approx. 8–10 Days

The product catalyzes within approximately 8–10 days. This does not mean the entire wall will be dry within 8–10 days; wall drying continues gradually after the chemical barrier develops.

Product Performance

Core Product Advantages

Designed for professional rising damp treatment, the system combines high fluidity, strong water-repellent performance and compatibility with porous masonry while maintaining wall breathability.

01

High Active Ingredient Content

Active ingredient content of ≥85% provides a strong technical basis for professional chemical DPC applications.

02

≥97% Water Absorption Reduction

A water absorption reduction of ≥97%, supporting its function as a water-repellent chemical barrier against capillary moisture.

03

High Fluidity & Excellent Wettability

The liquid material is designed to penetrate porous masonry and distribute through the wall section, helping create a continuous treatment zone.

04

Maintains Wall Breathability

The treated wall retains its original breathability, helping avoid formation of a dense surface film.

05

No Glossy, Sticky or Greasy Surface

After treatment, the surface does not become glossy, sticky or greasy, and the original wall color is not altered.

06

Solvent-Free Single-Component System

Single-component, solvent-free formulation simplifies professional handling and avoids the need for on-site multi-component mixing.

Technical Highlights

  • Active ingredient content ≥85%
  • Water absorption reduction ≥97%
  • Catalysis time: 8–10 days
  • Single-component
  • Solvent-free
  • Maintains wall breathability
Verified Product Data

DPC Injection Material Technical Data

Key technical parameters for evaluating YURU Premium Silane/Siloxane DPC Injection Material before specification, sample testing or bulk purchasing.

PropertySpecification
SystemSingle-component
Base ChemistryReactive polydimethylsiloxanes in emulsion
AppearanceColorless or yellowish liquid
pH12.5 ± 1
Active Ingredient Content≥85%
Water Absorption Reduction≥97%
Solvent ContentSolvent-free
StabilityNo delamination, oil separation or obvious precipitation
Permeability Pressure Ratio≥300%
Penetration Height Ratio≤30%
48 h Water Absorption Ratio≤65%
Reinforcement CorrosionNo corrosion effect
Main FunctionChemical barrier against capillary rising damp
Catalysis Time8–10 days

Need Full Technical Documentation?

Request the latest product data sheet, application information and product sample for technical evaluation before project use or bulk ordering.

Technical Data Note

Actual application performance can be influenced by masonry type, wall porosity, moisture condition and installation method. Refer to the latest TDS and application instructions before project use.

Masonry Compatibility

Suitable Masonry Materials

The high-fluidity silane/siloxane system is designed for professional injection into a range of porous masonry materials affected by capillary rising damp.

Brick Masonry

Suitable for different brick masonry formats listed in the product instructions, including red, solid, hollow and Roman brick.

Red Brick
Solid Brick
Hollow Brick
Roman Brick

Stone Masonry

Designed for porous stone-based masonry where the liquid can penetrate and distribute through the treated wall section.

Stone Masonry
Rubble Stone
Rubble Masonry

Concrete Blocks

Applicable to solid and hollow concrete block masonry as specified in the product application fields.

Solid Concrete Block
Hollow Concrete Block
Concrete

Tuff & Calcarenite

Suitable for porous mineral masonry such as tuff and calcarenite.

Tuff
Calcarenite

Sandstone & Limestone

Suitable for sandstone and limestone masonry where wall porosity and injection conditions allow effective material distribution.

Sandstone
Limestone

Clay & Mixed Masonry

Can be applied to clay blocks, cavity masonry and selected mixed masonry constructions listed in the application guidance.

Clay Blocks
Cavity Masonry
Cavity Masonry
Masonry Absorption Varies

Consumption and distribution can vary significantly with wall material, thickness, porosity and internal void structure. For irregular, cavity or historic masonry, preliminary assessment and sample application are recommended before confirming project consumption.

Application Parameters

Recommended Injection Parameters

Recommended drilling and injection parameters for professional installation of a chemical DPC barrier in masonry affected by rising damp.

ParameterRecommendation
Hole DiameterApprox. 12 mm
Hole Spacing10–12 cm
Hole DepthApprox. 2/3 of wall thickness
Packer Size12/16 mm multi-hole packer
Injection MethodPressure injection or gravity feed
Pressure EquipmentPneumatic or electric variable-pressure pump
Hole CleaningBlow out drilling dust before injection
Typical Hole PositionNear the lower wall zone
Hole ClosureApprox. 30 days after injection
Closure MaterialGypsum-free mortar or suitable filler

Professional Application Required

The product is intended for professional use. Final hole spacing, injection pressure and material quantity should be adjusted according to masonry porosity, internal voids, wall thickness and moisture condition.

Material Estimation

DPC Injection Material Estimated Consumption

Estimate the required DPC injection liquid according to wall thickness before confirming project quantity or bulk purchasing.

Theoretical Consumption Formula
0.25 L × Wall Thickness (cm) × Wall Length (m)

Estimated theoretical quantity based on the product data sheet.

20 cm Wall Thickness

Approx. 5 L / m

0.25 L × 20 cm = approximately 5 L of material per linear metre of wall.

30 cm Wall Thickness

Approx. 7.5 L / m

0.25 L × 30 cm = approximately 7.5 L of material per linear metre of wall.

40 cm Wall Thickness

Approx. 10 L / m

0.25 L × 40 cm = approximately 10 L of material per linear metre of wall.

Example Project Calculation

Wall thickness: 30 cm

Wall length: 20 m

Standard packaging: 25 L container

Calculation: 0.25 × 30 × 20 = 150 L

Approx. 150 L

Theoretical material requirement = approximately 6 × 25 L containers

Theoretical Estimate Only

Actual consumption can vary with masonry type, porosity, internal voids, wall thickness and injection method. Irregular, rubble or cavity masonry may require additional material compared with dense and uniform masonry.

Buyer Comparison

Liquid DPC Injection vs DPC Injection Cream

Both liquid and cream-based DPC systems are used in rising damp treatment, but they differ in material form, installation method and how they distribute through masonry. The appropriate system depends on wall construction, porosity, equipment and project requirements.

Selection FactorYURU Liquid DPC InjectionDPC Injection Cream
Material FormHigh-fluidity liquidCream / paste-like material
Application MethodPressure injection or gravity feedCommonly introduced through drilled holes using cartridge or injection equipment
DistributionDesigned to absorb and distribute through porous masonryDesigned to disperse from the drilled injection zone
Professional Pump UseSupportedOften not required, depending on system
Gravity ApplicationSupportedGenerally not the main application method
Masonry AssessmentPorosity and internal voids affect consumption and distributionMasonry condition also affects product distribution
Material QuantityCalculated according to wall thickness and lengthUsually determined by hole size, spacing and manufacturer guidance
Best Selection BasisWall structure, porosity, injection method and project requirementWall structure, application simplicity and product-specific guidance

Which System Should You Choose?

Don’t select a DPC system only by whether it is liquid or cream. Wall thickness, porosity, cavity structure, internal voids, installer equipment and required distribution should be evaluated first. YURU Premium Silane/Siloxane DPC Injection Material is designed as a high-fluidity liquid system for professional pressure or gravity injection.

01

High Fluidity

Supports absorption and distribution through porous masonry.

02

Pressure or Gravity Application

Allows different professional injection approaches according to wall conditions.

03

Wall-section Distribution

Designed to spread through the treated masonry section rather than remain only around the drilled opening.

Technical Buyer Guide

Why Does Active Ingredient Content Matter in DPC Injection?

Active ingredient content is an important specification when comparing chemical DPC injection materials, but it should not be used as the only basis for product selection. Chemistry, water-repellent performance, masonry compatibility and application behavior should also be reviewed.

≥85%

ACTIVE INGREDIENT CONTENT

One Important Specification — Not the Whole Decision

YURU Premium Silane/Siloxane DPC Injection Material specifies an active ingredient content of ≥85%. 

However, active content alone does not describe how a DPC material will perform inside masonry. Buyers should also review the base chemistry, water absorption data, penetration and distribution behavior, suitable masonry types and recommended injection method.

Compare It with Performance Data

Active content should not be evaluated alone. The current YURU product data sheet also specifies a water absorption reduction of ≥97%.

Performance Depends on Masonry Interaction

A DPC injection liquid must also penetrate and distribute through the masonry. High fluidity, wettability, wall porosity and internal void structure influence practical application behavior.

Verify the Data Before Bulk Purchase

Distributors and project buyers should compare active content together with the latest TDS, application instructions, water absorption data and sample evaluation.

What Should Buyers Compare?

When evaluating DPC injection materials, review active ingredient content together with base chemistry, water absorption reduction, masonry compatibility, injection method, technical documentation and sample performance where appropriate.

Important Technical Distinction

“Active ingredient content ≥85%” should not be interpreted as “85% silane.” Product specifications should therefore be compared using the exact terminology stated in the technical documentation.

Buyer Selection Guide

DPC Injection Material Selection Checklist

Before selecting a chemical DPC injection material, compare the product chemistry, verified performance data, masonry compatibility, application method and technical documentation — not only the product name or active content.

STEP 1

Diagnose

Confirm that the moisture source is capillary rising damp.

STEP 2

Match

Match chemistry, masonry compatibility and application method.

STEP 3

Verify

Review measurable performance data and technical documents.

A product should only move to sample evaluation or bulk purchasing after these three checks are reasonably satisfied.

Supply Information

Packaging & Supply

Standard packaging and purchasing information for project buyers, distributors and building-material importers evaluating YURU Premium Silane/Siloxane DPC Injection Material.

Silane/siloxane DPC injection material

25 L

STANDARD PLASTIC CONTAINER

Product Form: High-fluidity liquid

System: Single-component

Solvent Content: Solvent-free

Main Application: Chemical DPC injection

Information to Prepare Before Requesting a Quote

Providing basic project and purchasing information helps us review your requirement more efficiently.
OEM & Private Label

OEM & Private Label DPC Injection Material

For distributors, importers and private-label building-material brands, YURU Waterproof can support OEM and branded supply programs based on confirmed packaging, labeling and market requirements.

01

Private Label Branding

Support for customer branding and private-label presentation can be discussed according to the target market and order requirements.

02

Label & Packaging Configuration

Label content, branding layout and packaging presentation can be reviewed before bulk production.

03

Technical Document Support

Product data sheet, application information and Safety Data Sheet can be provided for technical review and market preparation.

04

Sample Before Bulk Order

Where appropriate, buyers can evaluate the product before confirming a distributor program or bulk order.

Typical OEM / Private Label Process

Confirm Requirement

Target market, application and expected quantity.

Branding & Packaging

Confirm label, branding and packaging requirements.

Review Sample / Data

Review technical information and product evaluation.

Approve Production

Confirm final product and packaging details.

Export & Delivery

Arrange supply according to final order terms.

Target Buyers & Professional Users

Who Is This Product For?

Premium Silane/Siloxane DPC Injection Material is intended for professional rising damp treatment and supply channels serving masonry repair, damp-proofing and building maintenance markets.

01

Waterproofing Material Distributors

Distributors supplying professional waterproofing and damp-proofing materials to contractors and local construction markets.

02

Building Material Importers

Importers looking for a specialized liquid DPC injection product for rising damp and masonry treatment portfolios.

03

Damp-proofing Contractors

Professional contractors carrying out chemical DPC injection and rising damp treatment in brick, stone and block masonry.

04

Masonry Repair & Restoration Contractors

Contractors working on older or moisture-affected masonry where capillary rising damp has been identified.

05

Building Maintenance Companies

Maintenance providers managing damp-wall remediation in residential, commercial or public buildings.

06

Private Label / Regional Brands

Building-material brands seeking OEM or private-label DPC injection products for local distribution.

Professional Use Only

This product is intended for professional application. Moisture diagnosis, masonry assessment and appropriate injection equipment should be considered before use.

Frequently Asked Questions

FAQ About Silane/Siloxane DPC Injection Material

Technical and purchasing questions commonly considered when evaluating liquid DPC injection material for rising damp treatment.

What is Premium Silane/Siloxane DPC Injection Material used for?

It is designed to create a chemical damp-proof barrier against capillary rising damp in porous masonry walls such as brick, stone and concrete blocks.

Is this product a liquid or a DPC injection cream?

YURU Premium Silane/Siloxane DPC Injection Material is a high-fluidity liquid system, not a paste-type injection cream. It can be applied by pressure injection or gravity feed.

What masonry materials can be treated?

Brick, stone masonry, rubble masonry, tuff, clay blocks, hollow brick and solid or hollow concrete blocks among the treatable materials.

How far apart should the injection holes be?

The current product instructions recommend approximately 10–12 cm spacing, with holes about 12 mm in diameter and drilled to roughly two-thirds of the wall thickness.

Can the product be applied by gravity?

Yes. The product can be applied either by pressure injection or by gravity using suitable equipment, depending on the selected application method and wall condition.

How much DPC injection liquid is required?

The theoretical estimate is approximately 0.25 L for each centimetre of wall thickness per linear metre. Actual consumption varies with wall type, porosity, thickness and internal voids.

How long does the product take to catalyze?

A catalysis time of approximately 8–10 days. This does not mean the entire wall will be dry within that period; wall drying continues gradually afterward.

Can I request a sample, technical data or private label supply?

Buyers can request technical product information and discuss sample evaluation, bulk supply and private-label requirements before confirming an order.

Technical & Purchasing Support

Need a DPC Injection Material for Your Market or Project?

Whether you are evaluating a rising damp project, sourcing for distribution, or developing a private-label product line, YURU Waterproof can support your next step with technical product information, sample evaluation and purchasing discussion.

01

Request Technical Data

Review product specifications, application information and technical parameters before selection.

02

Request Product Sample

Evaluate the liquid DPC injection material before bulk purchasing or distributor cooperation.

03

Request Bulk Order Quote

Send your required quantity, destination country and project or distribution requirement.

04

Discuss OEM / Private Label

Discuss branding, labeling and packaging requirements for your target market.

To Help Us Review Your Requirement Faster, Please Provide:

Not sure which information to prepare? Send us your project photos or basic purchasing requirement and our team can help you identify the next step.

Ask for Quote Now

Download Catalogue!

Download our catalog to check all of our products, select the right waterproof products for your projects.